LC2H Preset Counters

Catalog (PDF)
English
CAD Data
List

PRESET COUNTER

RoHS compatible UL CSA Marking CE Marking

Features

1.Preset function equipped in half size (24 × 48 mm/ 0.945 × 1.890 inch).

2.Display has backlight for instant recognition.

3.8.7 mm/ 0.343 inch Character Height (previously 7 mm/ 0.276 inch)

Easy-to read character height increased from 7 mm to 8.7 mm/ 0.276 inch to 0.343 inch.

4.Plenty of Digits

5.Counting Speed Switchable between 30 Hz and 5 kHz

6.Conforms to IP66 Protective Construction (Front panel surface)

Weatherproofing supported by using optional mounting frame and rubber gasket

7.Includes reassuring lock mode and lock switch to prevent erroneous operation.

8.Screw terminals are constructed to protect fingers to ensure safety.

9.Compliant with UL, c-UL and CE.

Return to top

Operation Mode

Output mode Operation Example when input mode is either addition or Subject:ubtraction
Output maintain/
hold count
[HOLD-A]
Output control is maintained after count-up completion and until resetting.
During that time, the count display does not change from that at count-up completion.
Output maintain/
over count
[HOLD-B]
Output control is maintained after count-up completion and until resetting. However, counting is possible despite completion of count-up.
One shot/
over count
[SHOT-A]
Output control is maintained after count-up completion for a fixed time (approx. 1 sec.). Counting is possible despite completion of count-up.
One shot/
recount I
[SHOT-B]
Output control is maintained after count-up completion for a fixed time (approx. 1 sec.). Counting is possible despite completion of count-up. However, reset occurs simultaneous with completion of count-up. While output is being maintained, restarting of the count is not possible.

Return to top

Part Names

Part names
Notes:1.Make the switch setting before installing to panel.
2.Please turn the power off if you change the setting of the count speed switch when the power is on. The setting will become valid when the power is turned back on.

1.Front reset key

This key resets the count value. It does not work when the lock switch is ON.

2.Mode key

Use to switch between each mode.

3.Setting key

Used to set digits of preset values or set each mode.

4.Set key

Use to set preset values or to switch between modes.

5.Lock switch

Disable the operation of the front panel reset key and the mode key. With the lock switch on, is displayed for about two seconds when the reset key or mode switch is operated.

6.Count speed switch

Use this switch to switch the count speed between 30 Hz and 5 kHz.

Return to top

Global Sales Network
If you have a question about our products or anything else, feel free to contact us at anytime.
Discontinued Products
Information is given about products that have been discontinued. Please use to verify specifications, etc.

Actions for Disuse of Environmental Impact Chemical Substances
This introduces what we are doing to reduce environmental problems. You can search for and verify in table format products that comply with the RoHS Directive.

Return to top

© Panasonic Electric Works Co., Ltd. 2010